The refrigerator compressor does not work because the ambient temperature is too low, the PTC starter fails, and the overload protector fails.
1. When the ambient temperature is too low (1~10℃), if the refrigerator is in manual compensation mode, you need to open the compensation switch. If the magnetic temperature compensation switch, you need to check whether the magnetic switch is normal: because the ambient temperature is too low, especially For refrigerators with dual-temperature single-control refrigerators, as long as the compressor works for a short period of time, the refrigerator compartment reaches a predetermined temperature (1 ~ 10 ℃). At the same time, due to the low ambient temperature, the temperature of the refrigerator compartment rises slowly or not, the compressor If it does not work for a long time, the shutdown time is too long, which causes the temperature of the freezer to be too high to reach below -18℃. When the ambient temperature is lower than 0 ℃, the refrigerator should be stopped: because the ambient temperature is lower than 0 ℃, the compressor oil becomes thicker and the lubrication performance becomes worse; at the same time, the condensation pressure becomes lower and the refrigerant will not flow into the evaporator. If you continue to use the refrigerator will not work properly and may cause damage to the compressor.
2. Failure of the PTC starter. Use a multimeter ohm file to measure whether the resistance of the PTC starter's running jack and the start jack is normal (the normal resistance is between 16 and 50 ohms under normal conditions). If it is infinite or 0, the PTC starter is damaged and should be replaced. .
3. The overload protector is faulty. Use an ammeter to measure whether the compressor starts and the operating current is normal (the starting current is generally about 5 to 8 times the operating current). If the current is normal and the overload protector is activated, the overload protector fails and should be replaced. Otherwise, the compressor is faulty.
4. Internal failure of the compressor. If the tested compressor accessories are normal, but the compressor still cannot be started, and the overload protector acts (the measured starting current is too large at this time), it is determined that the compressor is stuck in the cylinder or the compressor holds the shaft, and the compressor needs to be replaced.